Data Center Expansion: 5 Fire Protection Considerations You Shouldn’t Overlook
Expanding a data center takes careful planning, especially when the facility needs to remain operational throughout construction. While project teams focus on increasing capacity and minimizing downtime, it’s important to consider how the work could affect existing fire protection systems.
The more important question may be: What does this change mean for the fire protection systems already protecting the facility?
A data center can look very different after an expansion, renovation, or equipment upgrade than it did when its fire protection systems were originally designed. That does not mean every project requires major changes to those systems. It does mean that certain types of changes should prompt a closer look.
Here are five changes worth reviewing before your next project gets underway.
1. The Physical Space Is Changing
Even a relatively small change to a room’s layout can affect the area an existing fire protection system was designed to protect. For example, dividing a server room into two separate spaces may warrant reviewing the placement of existing detection equipment. The system may not need to change, but that should be confirmed before construction is complete.
2. The Equipment or Hazard Is Changing
As data centers increase capacity, they may introduce equipment that wasn’t part of the original fire protection design. Changes to battery systems or UPS infrastructure can be especially important to review because they may introduce different fire protection considerations.
A review during the planning phase can help determine whether the existing detection and suppression systems remain appropriate for the new equipment.
3. Airflow or Environmental Conditions Are Changing
Cooling and airflow are critical to data center operations. They can also be part of the fire protection conversation.
Changes to cooling systems, ventilation, raised floors, ceilings, or airflow patterns can change the environment within a protected space.
Significant airflow changes may also affect how smoke moves through a room, which can be relevant to the performance of certain detection systems.
| Hypothetical example: A facility changes its cooling strategy as part of an expansion. The fire protection equipment stays in the same locations, but airflow through the server room changes significantly.
The system did not move, but the environment around it did. Reviewing the detection strategy before the new cooling configuration is operational can help identify whether any adjustments are needed. |
4. The Use of the Space Is Changing
Sometimes the biggest change is not what is physically happening in a room, but what the room is being used for.
For example, converting a storage room into an equipment room can change the hazards associated with that space, even if the room itself stays exactly the same.
But the original protection was designed for the space as it was being used at the time.
When the purpose of the space changes, it is worth asking whether the fire protection strategy should change with it.
5. The Project Will Affect an Existing Fire Protection System
This one is more obvious, but it is still worth calling out because it can get complicated quickly.
Construction can directly affect existing fire protection systems, particularly when work is taking place inside an operating data center. Equipment may need to be relocated, or portions of a system may need to be temporarily taken offline.
| Hypothetical example: A data center is expanding into an adjacent area while the existing facility remains fully operational. During construction, temporary walls are installed and contractors need to work around existing fire protection equipment. A portion of the system also needs to be temporarily taken offline.
The finished project may have a perfectly sound fire protection design. But the facility still has to manage the months in between. That temporary period deserves planning, too. |
Don’t Just Plan for the Finished Facility
One of the easiest things to overlook during a data center project is the facility that exists during construction.
There is the facility you have today.
There is the facility you are building.
And then there is everything that happens in between.
Construction introduces conditions that weren’t part of the original facility design. Temporary partitions can affect access, while hot work may require additional precautions. Existing fire protection systems may also need to be temporarily impaired to accommodate the work.
Those temporary conditions can create a very different operating environment than either the original facility or the finished expansion.
When a fire protection system must be taken offline, impairment procedures and appropriate interim safety measures need to be addressed before work begins. This is especially important when the data center must remain operational during construction.
Ask These Questions Before Your Next Project Starts
If you are planning a data center expansion, renovation, equipment upgrade, or other major facility change, start with five simple questions:
- Are we changing the physical layout?
- Are we adding, removing, or relocating equipment or infrastructure?
- Are we changing electrical, mechanical, cooling, or airflow conditions?
- Are we changing how an existing space is used?
- Will construction affect, obstruct, modify, or temporarily take any fire protection system offline?
You do not need every answer to be “yes” for a project to warrant a conversation.
The goal is simply to identify changes early enough that the right people can evaluate what they mean for the facility’s fire protection.
Why Early Review Matters
The earlier a potential fire protection issue is identified, the more options a project team generally has for addressing it.
Once construction is underway, walls may already be installed. Equipment may already be ordered. Contractors may already be scheduled. Changes that could have been incorporated during design can become more complicated when everyone is working around an active construction project.